Controller Failure Alarm

acBoardControllerFailureAlarm

Alarm

acBoardControllerFailureAlarm

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.9

Description

The alarm is sent in the following scenarios:

FXO-supporting products only: Physical FXO port is up or down (Out-of-Service or OOS). The FXO line can be down due to, for example, port disconnected or insufficient current and voltage. (Syslog message event is ANALOG_IF_LINE_DISCONNECTED.)
Digital-supporting products only: Physical BRI or PRI (E1/T1) port is up or down (OOS).
Proxy is not found or registration fails. In such a case, the device's routing table may be used for routing instead of the Proxy.
Connection to the Proxy is up or down.
Digital-supporting products only: Failure in TDM-over-IP call - transparent E1/T1 without signalling.
Analog or Digital supporting products only: Connection to the Proxy Set associated with the trunk/line is up/down.
Analog or Digital supporting products only: Failure in server registration for the trunk/line.
Analog or Digital supporting products only: Failure in a Serving IP Group for the trunk.
Failure in a Proxy Set.

Default Severity

Major

Source Varbind Text

Board#1

Event Type

processingErrorAlarm

Probable Cause

softwareError (46)

Severity

Condition

Text

Additional Information

Major

Failure in a Proxy Set

"Proxy Set ID n"

Where n represents the Proxy Set ID.

 

Proxy has not been found or registration failure

"Proxy not found. Use internal routing"
- or -
"Proxy lost. Looking for another Proxy"

Check the network layer
Make sure that the proxy IP and port are configured correctly.

Connection to Proxy is down

"BusyOut Trunk/Line n Connectivity Proxy failure"

-

Connection to the Proxy Set associated with the trunk or line is down

"BusyOut Trunk/Line n Proxy Set Failure"

Where n represents the BRI / PRI trunk or FXO line.

Note: Applicable only to analog and digital supporting products.

Failure in TDM-over-IP call

"BusyOut Trunk n TDM over IP failure (Active calls x Min y)"

Where n represents the BRI / PRI trunk.

Note: Applicable only to digital supporting products.

Failure in server registration for the trunk/line

"BusyOut Trunk/Line n Registration Failure"

Where n represents the BRI / PRI trunk or FXO line.

Note: Applicable only to analog and digital supporting products.

Failure in a Serving IP Group for the trunk

"BusyOut Trunk n Serving IP Group Failure"

Where n represents the BRI / PRI trunk ID.

Note: Applicable only to digital supporting products.

FXO physical port is down

"BusyOut Line n Link failure"

Where n represents the FXO port number (0 for the first port).

Verify that the FXO line is securely cabled to the device's FXO port.

Note: Applicable only to analog FXO supporting products.

BRI or PRI physical port is down

"BusyOut Trunk n Link failure"

Where n represents the BRI / PRI trunk port number (0 for the first port).

Verify that the digital trunk is securely cabled to the device's digital port.

Note: Applicable only to digital supporting products.

Cleared

Proxy is found. The 'Cleared' message includes the IP address of this Proxy.

-

-